close Close
phone_iphone +46 (0)8 531 940 00

3-Phase Dust Extractors, Abatement & Decontamination Specialist, Construction, H-Line (Asbestos) Dust Extractors, Industry, Mobile Dust Extractors

DC 5900 H Asbestos

DC 5900 H Asbestos, 9,2 kW, P 400V, 50/60 Hz, Y/D-start

  • Certified at the ”The Institute for Occupational Safety and Health of the German Social Accident Insurance (IFA)” for extracting/removing dry, non flammable, non conductive, hazardous and carcinogenic particles, including asbestos
  • Designed to cope with large amounts of dust and for continuous operation
  • Ergonomic chassis
  • Tiltable cyclone for easier service and filter change
  • Phase error indicator*
  • High reliability in operation

*If a phase error is detected a lamp on the machine will come on.

3-phase 3-phase
H 3rd Party H 3rd Party
Asbest Asbest
Select model
  • Model Part no
    Request
  • 400 V /50 Hz /9.2 kW P
    119350
    Request
  • 400 V /50 Hz /9.2 kW S
    119360
    Request
  • 400 V /50 Hz /4 kW
    119370
    Request

The DC 5900 H Asbestos is certified by the German IFA* to be used to extract/remove dry, non flammable, non conductive, hazardous and carcinogenic particles, including asbestos.

DC 5900 H Asbestoscan can handle large amounts of dust in continuous operation. Like the DC 1800 H and DC 3800 H, the machine is the result of many years of field tests and cooperation with the decontamination and abatement industry. It complies with both the needs and requirements of the industry.

The extraction system functions with negative pressure (vacuum) that draws the air through suction casings/nozzles, hose system, separator and filter system. Coarse separation of dust occurs in the unit’s cyclone which is a highly efficient separator for larger particulate. The fine dust is separated and contained by the unit´s filter system. Separated material is collected for disposal in the plastic sack or container at the base of the cyclone.

Filter cleaning with reverse pulse gives long filter life and constant capacity.

* The Institute for Occupational Safety and Health of the German Social Accident Insurance (=IFA)

HxWxD [mm]

1942x780x1160

Weight [kg]

176 (4kW)/210 (9.2kW P)/210 (9.2kW S)

Inlet Ø [mm]

76 (4kW)/108 (9.2kW P)/76 (9.2kW S)

Hose length Ø50mm [m]

5-30

Collecting container [l]

75

Max. flow fan (EU) [m3/h]

470 (4kW)/800 (9.2kW P)/500 (9.2kW S)

Negative pressure max. (EU) [kPa]

28 (4kW)/28 (9.2kW P)/40 (9.2kW S)

Power [kW]

4 (4kW)/9.2 (9.2kW P)/9.2 (9.2kW S)

Fine filter polyester, area [m2]

5 (4kW)/8.4 (9.2kW P)/8.4 (9.2kW S)

Degree of separation fine filter, EN 60335-2-69, Class M [%]

99.9

HEPA filter, area [m2]

2.7

Filter classification HEPA filter, EN 1822-1

HEPA H13

Degree of separation machine, EN 60335-2-69, Appendix A-A, Class H [%]

99.995

Max. sound level [dB(A)]

75

3-Phase Dust Extractors, Abatement & Decontamination Specialist, Construction, H-Line (Asbestos) Dust Extractors, Industry, Mobile Dust Extractors

DC 5900 H Asbestos

DC 5900 H Asbestos, 9,2 kW, P 400V, 50/60 Hz, Y/D-start

  • Certified at the ”The Institute for Occupational Safety and Health of the German Social Accident Insurance (IFA)” for extracting/removing dry, non flammable, non conductive, hazardous and carcinogenic particles, including asbestos
  • Designed to cope with large amounts of dust and for continuous operation
  • Ergonomic chassis
  • Tiltable cyclone for easier service and filter change
  • Phase error indicator*
  • High reliability in operation

*If a phase error is detected a lamp on the machine will come on.

3-phase 3-phase
H 3rd Party H 3rd Party
Asbest Asbest
Select model
  • Model Part no
    Request
  • 400 V /50 Hz /9.2 kW P
    119350
    Request
  • 400 V /50 Hz /9.2 kW S
    119360
    Request
  • 400 V /50 Hz /4 kW
    119370
    Request

Related products

Dustcontrol UK Ltd., 7 Beaufort Court , Roebuck Way Knowlhill, Milton Keynes MK5 8HL