The DC 11-Module XL is a complete central unit for source extraction and industrial cleaning. The unit can manage just about every kind of dust and chip you can imagine, even coolants and emulsions when equipped with a preseparator. The XL-model can handle more extraction points at a time than the standard model.
We also recommend our customers to equip the DC 11-Module XL with our unique energy saving DC Green System. Depending on the number of open outlets, the RPM of the vacuum provider is optimized, generating just as much vacuum as you need. By using sophisticated on-demand control with a frequency converter, the maximum performance is also increased compared to a normal system. Due to this the DC Green System can give you potentially energy savings from 40% up to 90%.
To show our commitment for sustainability, we have now reduced the pricing of all DC Green Systems to lower the initial investment and enable more of our users to benefit from lower energy costs and reduced carbon footprint.
Note: The product picture is not showing the standard version.
TECHNICAL DATA | 15 kW | 20 hp P | 18.5 kW S | 25 hp S |
Motor [Hz] | 50 | 60 | 50 | 60 |
Pump [rpm] | 4000 | 4000 | 4300 | 4300 |
Inlet Ø [mm/in] | 108/4.2 | 108/4.2 | 108/4.2 | 108/4.2 |
Outlet Ø [mm/in] | 160/6.2 | 160/6.2 | 160/6.2 | 160/6.2 |
Max dp [kPa] | 26* | 28 | 28* | 28 |
Nominal pressure [kPa] | 20 | 20 | 20 | 20 |
Flow [m3/h/cfm] | 1000/589 | 1000/589 | 1000/589 | 1000/589 |
Sound level 1 m [dB(A)] | 66 | 66 | 66 | 66 |
* DC Green System max 22 kPa |
AIR FLOW* [m3/h/cfm] | Vacuum level required | Select unit |
600-800/353-470 | normal | DC 11-Module 5.5/7.5 kW |
200-400/118-235 | large | DC 11-Module 11 kW S |
* Always consider dust type and filter loading as above. |
For more detailed information, please read our