Cellulose Fine Filter
Good quality standard filter with high filtration efficiency. Epoxy treated for resistance to humidity and other elements.
Polyester Fine Filter
High quality filter material with exceptional resistance to most elements. Particularly suitable to high humidity applications such as machine and tool shops where cutting and cooling fluids are used. Filter can be washed.
HEPA Filter
The HEPA filter is made of fibreglass material with a support layer of cellulose. Filtration efficiency is 99.995% EN 60335. Note: When changing filters the gasket of the filter holder has to be checked and cleaned. Leakage is not permitted in Asbestos applications.
DC 2500i, DC 2500, DC 2500 Twin | ||||||
Part No | Description | Construction | Material | Area [m2 /ft2] | Classification | Max temp |
4889 | Fine filter | Pleated | Polyester | 1.4 /15 | IEC EN 60335-2-69 Part 1 | 266°F /130°C |
404901 | Fine filter | Pleated around support cylinder |
Cellulose | 1.5 /16.2 | IEC EN 60335-2-69 Part 1 | 158°F /70°C |
4821 | HEPA filter K | Pleated | Cellulose, fibreglass | 1.5 /16.2 | HEPA H13 EN 1822-1 | 158°F /70°C |
4133 | HEPA filter (fitted in the fine filter) |
Pleated around support cylinder |
Cellulose, fibreglass | 0.5 /5.4 | HEPA H13 EN 1822-1 | 176°F/80°C |
DC 2700c, DC 2700i, DC 2800c, DC 2800c Rental |
||||||
Part No | Description | Construction | Material | Area [m2 /ft2] | Classification | Max temp |
4889 | Fine filter | Pleated | Polyester | 1.4 /15 | IEC EN 60335-2-69 Part 1 | 266°F /130°C |
404901 | Fine filter | Pleated around support cylinder |
Cellulose | 1.5 /16.2 | IEC EN 60335-2-69 Part 1 | 158°F /70°C |
4821 | HEPA filter K | Pleated | Cellulose, fibreglass | 1.5 /16.2 | HEPA H13 EN 1822-1 | 158°F /70°C |
4133 | HEPA filter (fitted in the fine filter) |
Pleated around support cylinder |
Cellulose, fibreglass | 0.5 /5.4 | HEPA H13 EN 1822-1 | 176°F/80°C |
DC 3700c |
||||||
Part No | Description | Construction | Material | Area [m2 /ft2] | Classification | Max temp |
42026 | Fine filter | Pleated around support cylinder |
Cellulose | 1.8 /19.4 | IEC EN 60335-2-69 Part 1 | 176°F/80°C |
42025 | Fine filter | Pleated around support cylinder |
Polyester | 1.8 /19.4 | IEC EN 60335-2-69 Part 1 | 176°F/80°C |
DC 3500, DC 3500TR, DC 3500 Stationary, DC 5500, DC 5500i |
||||||
Part No | Description | Construction | Material | Area [m2 /ft2] | Classification | Max temp |
408801 | Fine filter | Pleated | Polyester | 1.6 /17 | IEC EN 60335-2-69 Part 1 | 176°F/80°C |
408803 | Fine filter | Pleated | Cellulose | 1.6 /17 | IEC EN 60335-2-69 Part 1 | 176°F/80°C |
4821 | HEPA filter, DC 3500 TR | Pleated | Cellulose, Fibreglass | 1.5 /16.2 | HEPA H13 EN 1822-1 | 158°F /70°C |
4366 | HEPA filter, DC 3500 (installed on exhaust) |
Pleated around support cylinder |
Cellulose, Fibreglass | 1.2 /12.9 | HEPA H13 EN 1822-1 | 176°F/80°C |
4422 | HEPA filter, DC 5500 5 kW, 9.2 kW S (installed under top cover) |
Pleated around support cylinder |
Cellulose, Fibreglass | 2.5 /26.9 | HEPA H13 EN 1822-1 | 176°F/80°C |
4017 | HEPA filter, DC 5500 9.2 kW P (installed on exhaust) |
Pleated around support cylinder |
Cellulose, Fibreglass | 2.8 /30 | HEPA H13 EN 1822-1 | 176°F/80°C |
DC 3500i, DC 5700c, DC 5800 a/c 5 kW, DC 5800 a/c PTFE |
||||||
Part No | Description | Construction | Material | Area [m2 /ft2] | Classification | Max temp |
4917 | Combi-filter DC 3500i (Fine filter + HEPA H13 filter) |
Pleated | Cellulose, fibreglass | 1.5 /16.2 | HEPA H13 EN 1822-1 | 176°F/80°C |
4422 | HEPA filter, DC 5700 5 kW, 9.2 kW S (installed under top cover) |
Pleated around support cylinder |
Cellulose, fibreglass | 2.5 /26.9 | HEPA H13 EN 1822-1 | 176°F/80°C |
4017 | HEPA filter, DC 5700 9.2 kW P (installed on exhaust) |
Pleated around support cylinder |
Cellulose, fibreglass | 2.8 /30 | HEPA H13 EN 1822-1 | 176°F/80°C |
Air Cleaners DC 380, DC 1500, DC AirCube |
||||||
Part No | Description | Construction | Material | Area [m2 /ft2] | Classification | Max temp |
4080 | Pre-filter, DC 380/DC AirCube | Carpet | Polyester | 0.1 /1 | IEC EN 60335-2-69 Part 1 | 212°F/100°C |
4669 | Pre-filter, DC 1500 | Carpet | Polyester | 0.3 /3.2 | IEC EN 60335-2-69 Part 1 | 212°F/100°C |
42136 | HEPA filter, DC AirCube | Pleated HEPA filter box |
Glasfaser | 5.2 /55.9 | EN 1822-1, HEPA H13 | 212°F/100°C |
DC 3800a/c, DC 3800c Turbo, DC 3800 Turbo EX, DC 3800c Twin, DC 3800 TR S, DC 3800i, DC 3800 Stationary |
||||||
Part No | Description | Construction | Material | Area [m2 /ft2] | Classification | Max temp |
42026 | Fine filter | Pleated around support cylinder |
Cellulose | 1.8 /19.4 | IEC EN 60335-2-69 Part 1 | 176°F/80°C |
42025 | Fine filter | Pleated around support cylinder |
Polyester | 1.8 /19.4 | IEC EN 60335-2-69 Part 1 | 176°F/80°C |
42465 | Fine filter, PTFE | Pleated around support cylinder |
Polyester, PTFE | 1.8 /19.4 | IEC EN 60335-2-69 Part 1 | 176°F/80°C |
42024 | HEPA filter | Pleated around support cylinder |
Cellulose, Fibreglass | 1.5 /16.2 | HEPA H13 EN 1822-1 | 176°F/80°C |
42398 | Fine filter, grounded | Pleated around support cylinder |
Polyester | 1.8 /19.4 | IEC EN 60335-2-69 Part 1 | 176°F/80°C |
4202501 | Fine filter antistatic | Pleated around support cylinder |
Polyester, antistatic | 1.5 /16.2 | IEC EN 60335-2-69 Part 1 | 176°F/80°C |
For more detailed information, please read our