Turbopumps with TPR designation are parallel connected twin impeller belt driven units. Cooling air is introduced into the unit through an adjustable vacuum relief valve. The vacuum pressure in the system can be held constant when different outlets are opened. The turbopumps are equipped with thermal overload protection on the outboard bearing which will trip out when bearing temperature becomes excessive. A back flow valve is built into the unit on the inlet side.
TECHNICAL DATA | TPR 35 | TPR 40 | TPR 43 | TPR 47 | TPR 50 |
Pump [rpm] | 3500 | 4000 | 4300 | 4700 | 5000 |
Weight [kg] | 400 | 400 | 430 | 450 | 530 |
Max dP [kPa] | 22 | 26 | 28 | 29 | 30 |
Nominal Pressure [kPa] | 20 | 20 | 20 | 21 | 23 |
Flow max [m3/h] | 1000 | 1200 | 1400 | 1500 | 1600 |
Sound Level of Unit 1 m [dB(A)] | 66 | 66 | 66 | 66 | 66 |
Inlet [Ø mm] | 160 | 160 | 160 | 160 | 160 |
Outlet [ Ø mm] | 160 | 160 | 160 | 160 | 160 |